Surgard integration
    • 13 Oct 2022
    • 1 Minute to read
    • Dark
      Light
    • PDF

    Surgard integration

    • Dark
      Light
    • PDF

    Article summary

    Surgard Automation Output Protocol format.

    Information necessary to set up integration:

    • IP address  and port
    • Default account identification:
      • Virtual Receiver number (usually constant 01) / Recipient number / Empfänger‐Nummer
      • Virtual Line number (usually constant) / Receiver channel / Kanal‐Nummer des Empfängers
      • Account ID / Objekt‐Identifizierer (Identnummer)
      • Zone Code / Zonen‐Nummer (zur genaueren Festlegung des Auslösepunktes; z.B. Kamera‐Nummer)

    In case TLS used:

    • SSL certificate (if self-signed cert used)

    Description field format:

    Allows to configure Surgard:#<account_id>|<zone>, but not Virtual Receiver and Line number. Examples:

    Surgard:#12345|001

    Surgard:#12345

    Supported event types:

    Reconeyez

    SIA DCS 

    SystemStarted

    -

    SystemStopped

    -

    PersonDetected

    BA Burglary Alarm

    VehicleDetected

    BA Burglary Alarm

    MovementDetected

    BA Burglary Alarm

    RoutineCheck

    RP Automatic Test

    Tamper

    TA Tamper Alarm

    Armed

    CL Closing Report

    Disarmed

    OP Opening Report

    ConnectionLost

    YC Communication Fail

    DeviceConnected

    YK Communication Restore

    BatteryLow

    XT TX Battery Trouble

    BatteryRestored

    XR TX Battery Restoral

    CriticalBatteryShutdown

    YT System Battery Trouble

    CameraError

    -

    CameraTimeout

    -