Bold Group’s Manitou integration uses the Manitou FEP-XML Receiver Driver. Manitou standard system event codes are supported. Manitou requires all device GPS coordinates to be saved in order to accept alarms from the devices.
Information necessary to set up integration:
- Server IP address and port (preferably TCP)
- Default account identification and device info
- Account Number or Transmitter ID
- (optional?) Virtual line number (valid range 1-65534) or Pseudo-DNIS (variable length 1-20)
- (optional) Area value (variable length 0-4)
- (optional) Zone value (variable length 0-5)
Description field format:
Manitou:LRecon#9999|1-2
Supported event types:
Reconeyez event
| Bold Manitou
|
SystemStarted
| *SS Service start
|
SystemStopped
| *SE Service end
|
PersonDetected
| *BA Burglary alarm
|
VehicleDetected
| *BA Burglary alarm
|
MovementDetected
| *BA Burglary alarm
|
RoutineControl
| *S Supervisory
|
Tamper
| *TP Tamper
|
Armed
| *C Close
|
Disarmed
| *O Open
|
AutoArmed
| *CU Unscheduled Open
|
AutoDisarmed
| *OU Unscheduled Close
|
ConfigChanged
| -
|
ConnectionLost
| *OF Communication Fail
|
DeviceConnected
| *ON Communication Restoral
|
BatteryLow
| *L Low Battery
|
BatteryRestored
| *G Battery OK
|
CriticalBatteryShutdown
| *NB No battery
|
BatteryRemoved
| *NB No battery
|
CameraError
| -
|
CameraTimeout
| -
|
LidOpened
| *TP Tamper
|
AuxPowerLost
| *F AC Loss
|
AuxPowerFound
| *K AC Restore
|
IntBatChargingFault
| -
|
IntBatChargingNormal
| -
|