Patriot quickstart guide: http://www.patriotsystems.com/Downloads/QuickStartGuide.pdf

Patriot integration setup includes following steps:

  1. Create client in Patriot system, remember Client ID and Port ID
  2. In Reconeyez webui under each device add following line to "Description" textbox: "Patriot:<clientid>-<portid>" where <clientid> and <portid> are the numbers in the Patriot system. (Example: "Patriot:0011-01")
  3. Add zones in Patriot system. Each zone reflects one Reconeyez device. Add zone numbers to zones. Zone numbers are derived from Reconeyez device global unique ID. Check Reconeyez webui each device view and see device GUID on header row with grey background. From there take these characters 3-6 and convert these hexadecimal numbers to decimal (ie use https://www.binaryhexconverter.com/hex-to-decimal-converter). Take the decimal value and put it as zone number. Don't forget to tick the "camera enabled" box for detectors. Also see that "Standard Media" is selected. (Example: 018D353B1B00009C take "8D35" and convert to decimal which is "36149")
  4. Create e-mail to be polled by Patriot system. Get the pop3 server address and port.
  5. In Patriot system configure "System"->"Tasks"->"Email" settings so that "Recv Message Type" is "Standard Media", add server and port and your mail server credentials.
  6. In Patriot system configure  "System"->"System Settings"->"System wide settings"->"Misc settings"->"Camera/Video Settings" so that "Video Storage Folder" directs to desired location

Information necessary to set up integration:

  • SMTP server IP address and port
  • Recipient e-mail address
  • Default client ID and port number (the client and port field in Patriot UI)

Description field format:
Allows to overwrite default "Patriot:<clientid>-<portid>":

Patriot:0011-01


Supported event types:

Reconeyez
CID event
SystemStarted
-
SystemStopped
-
PersonDetected
1130 Burglar alarms
VehicleDetected
1130 Burglar alarms
MovementDetected
1130 Burglar alarms
Routine Check
1602 Periodic test report
Tamper
1137 Tamper
Armed
3400 Restore open/close
Disarmed
1400 New open/close
ConnectionLost
1350 Communication Trouble
DeviceConnected
3350 Restore communication trouble
BatteryLow
1302 Low system battery
BatteryRestored
3302 Restore Low system bat
CriticalBatteryShutdown
1308 System shutdown

Cet article vous a-t-il été utile ?