Manitou integration
    • 17 Aug 2023
    • 1 Minute to read
    • Dark
      Light
    • PDF

    Manitou integration

    • Dark
      Light
    • PDF

    Article summary

    Bold Group’s Manitou integration uses the Manitou FEP-XML Receiver Driver. Manitou standard system event codes are supported. Manitou requires all device GPS coordinates to be saved in order to accept alarms from the devices.

    Information necessary to set up integration:

    • Server IP address and port (preferably TCP)
    • Default account identification and device info
      • Account Number or Transmitter ID
      • (optional?) Virtual line number (valid range 1-65534) or Pseudo-DNIS (variable length 1-20)
      • (optional) Area value (variable length 0-4)
      • (optional) Zone value (variable length 0-5)

    Description field format:

    Manitou:LRecon#9999|1-2

    Supported event types:

    Reconeyez event
    Bold Manitou
    SystemStarted
    *SS Service start
    SystemStopped
    *SE Service end
    PersonDetected
    *BA Burglary alarm
    VehicleDetected
    *BA Burglary alarm
    MovementDetected
    *BA Burglary alarm
    RoutineControl
    *S Supervisory
    Tamper
    *TP Tamper
    Armed
    *C Close
    Disarmed
    *O Open
    AutoArmed
    *CU Unscheduled Open
    AutoDisarmed
    *OU Unscheduled Close
    ConfigChanged
    -
    ConnectionLost
    *OF Communication Fail
    DeviceConnected
    *ON Communication Restoral
    BatteryLow
    *L Low Battery
    BatteryRestored
    *G Battery OK
    CriticalBatteryShutdown
    *NB No battery
    BatteryRemoved
    *NB No battery
    CameraError
    -
    CameraTimeout
    -
    LidOpened
    *TP Tamper
    AuxPowerLost
    *F AC Loss
    AuxPowerFound
    *K AC Restore
    IntBatChargingFault
    -
    IntBatChargingNormal
    -